To the extent permitted by applicable law, no responsibility or liability is assumed by Schneider Electric and its subsidiaries for any errors or omissions in the informational content of this document, as well as any non-intended use or misuse of the content thereof. Schneider Electric reserves the right to make changes or updates with respect to or in the content of this document or the format thereof, at any time without notice. Schneider Electric does not grant any right or license for commercial use of the document or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. No part of this document may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of Schneider Electric. This document and its content are protected under applicable copyright laws and provided for informative use only. All other brands may be trademarks of their respective owner. The Schneider Electric brand and any trademarks of Schneider Electric SE and its subsidiaries referred to in this document are the property of Schneider Electric SE or its subsidiaries. It is the duty of any such user to perform or have any professional expert of its choice (integrator, specifier or the like) perform the appropriate and comprehensive risk analysis, evaluation and testing of the products/solutions with respect to the relevant specific application or use thereof. It is not to be used for determining suitability or reliability of the products/solutions for specific user applications. This document is not intended as a substitute for a detailed study or operational and site-specific development or schematic plan. ![]() For 200 Amp services, a 4 grounding electrode conductor (ground wire) is required. Ground wires for residences typically are made of copper and are 6 (6 AWG) or larger. However, these answers assume that there’s no voltage drop to consider. The ground wire, often referred to as the grounding electrode conductor, is the link between the ground rod and the service ground connection. For aluminum, it should at least be 4 AWG. According to the size chart recommendations from the 2002 edition of the NEC, the minimum wire for 50 amps should be 6 AWG for copper. The information provided in this document contains general descriptions, technical characteristics and/or recommendations related to products/solutions. The Correct Wire Sizes for a 50A Sub Panel. ![]() ![]() *ġ2 Refer to 240.4(D) for conductor overcurrent protectionġ0 Refer to 240.4(D) for conductor overcurrent *ġ4 Refer to 240.4(D) for conductor overcurrent protection limitations. THWN-2, RHH, RHW-2, USE-2, XHH, XHHW, XHHW-2, ZW-2įor conductor overcurrent protection limitations. Thus, 400-amp service would use two sets of 2/0 copper wire, one set for each 200-amp service. We are the voice of the electrical construction industry with over 70000 firms employing over. because their size and stiffness make them difficult to install. RHW-2, THHN, THHW, THW-2, THWN-2, USE-2, XHH, XHHW, XHHW-2, ZW-2 We are NECA, the National Electrical Contractors Association.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |